Axxius 800 - Release 2.2 10-11
OCU-DP Card
Alarms
Alarms
The OCU-DP cards and supporting Controller Software will support the following
alarms:
Alarm/
Event
Severity Category Description Clear Mechanism
(alarms only)
Card
Detect
Information Equipment OCU-DP card inserted
Card
Removed
Information Equipment OCU-DP card removed
Out of
Service
(OOS)
Major Facility Network sending Out-of-
Service code (OOS) or
card has LOS.
Correct with Network or
replace or deprovision the
card.
Los of
Signal
(LOS)
Major Facility No signal at customer link. Correct with Customer
data path, replace the card,
or reconnect the drop.
Los of
Frame
(LOF)
Major Facility Framing patter not
detected at customer link.
Correct with Customer
data path, replace the card,
or reconnect the drop.
Bipolar
Violation
(BPV)
Minor Facility Excessive violations on
customer interface.
Correct with the incoming
signal, or deprovision card.