1-8 Axxius 800 - Release 2.2
Base Platform
Technical Specifications
Alarm Connectors
The alarm contact outputs are per Telcordia definitions for visible and audible. They
operate per the spec with the exception that the audible outputs can be disabled with the
ACO button.
l The alarm output contacts are designed for use at 48V nominal with a current
draw of 0.5A maximum.
l The alarm inputs are dry contact with a current capacity of 10mA.
Network Standards
l ANSI/TIA - T1.403 ESF FDL
Management
l Craft Interface - front access from RS-232 (DB9) or 10/100Base-TX Ethernet
ports
l SNMP
l Dedicated Management DS0 for remote management access
Power
l DC Power: -48 VDC or +24 VDC, 120 W rated input
l OCU-DP and FXO Service cards require -48 VDC Power Supply
l Dual-feed power inputs located on rear panel
Physical Information
l Dimensions: 3.5 in. (H-2 RU) x 17.25 in. (W) x 12.5 in. (D)
8.9 cm (H) x 43.8 cm (W) x 31.75 cm (D)
l Weight: approximately 30 lbs. (13.6 kg) fully loaded
l Rack mount, 19 or 23 inch
Environment
See Installation Environment on page 2-3